A unit for loudness

Sone scale: how loudness doubles every 10 phons

By Phil Springer, Editor · Published · Name That Unit

Sone scale: how loudness doubles every 10 phons

The sone is a unit of subjective sound loudness, and the sone scale is anchored at one sone: the loudness of a pure tone at a frequency of one kilohertz and a strength of 40 decibels, according to the Dictionary of Units at ibiblio. A sound has loudness s sones if a listener judges it to be s times louder than a sound of one sone. The same dictionary says the sone is often used in industrial engineering to express the perceived loudness of engines, fans and other industrial equipment, and that its name comes from the Latin sonus, meaning sound. It credits S. S. Stevens and H. Davis with introducing the unit in 1938, while the Sengpiel Audio reference pages date Stevens's proposal to 1936.

Loudness is not the same thing as intensity. The sonic-studio handbook hosted by Simon Fraser University defines loudness as the subjective impression of the intensity or magnitude of a sound. It depends on frequency, waveform and duration, as well as sound intensity or sound pressure. It is expressed quantitatively in sones and phons for sine tones or narrow-band noise, and in perceived noise level for broad-band environmental sounds. Even for fairly simple sounds made of sinusoidal components, the Handbook says, measuring loudness is very difficult.

That is where the phon comes in. The Handbook describes the phon as a unit for the loudness level of a sound, based on equal-loudness contours. At 1,000 hertz, 0 phons is set at 0 decibels, the threshold of hearing at that frequency, and the relationship between the decibel and phon scales at 1,000 hertz is exact. Away from that frequency the phon curve varies considerably because of the way the ear discriminates for or against sounds of different frequencies. As an example, a very low 30 hertz rumble at 110 decibels is perceived as being only 90 phons. The Handbook adds that the phon describes only sounds that are equally loud: 40 phons is not twice as loud as 20 phons.

The sone scale supplies the missing proportionality. The Handbook says that an increase of 10 phons is sufficient to produce the impression that a sine tone is twice as loud, and that the sone scale of subjective loudness was invented for measuring sounds of different loudness. One sone is arbitrarily taken to be 40 phons at any frequency, at any point along the 40 phon curve. Two sones are twice as loud, 50 phons. Four sones are twice as loud again, 60 phons. The relationship is expressed by the equation phon = 40 + 10 log2(sone). Its pairing with the sone scale is compact: the ibiblio dictionary gives the same relation as a sound of p phons having loudness 2 to the power (p minus 40) divided by 10 sones.

Sengpiel Audio gives the same formula as the ISO recommendation ISO/R 131-1959 and says the conversion holds between 40 and 120 phons. Its table runs from 40 phons at 1 sone to 100 phons at 64 sones and 120 phons at 256 sones, with the dynamic markings ppp at 40 phons, p at 60, f at 80 and fff at 100. Below 40 phons it gives a separate formula valid from 8 to 40 phons. The number of sones per phon was chosen, Sengpiel explains, so that a doubling of the number of sones sounds to the human ear like a doubling of loudness. That corresponds to raising the sound pressure level by 10 decibels, or increasing sound pressure by a ratio of 3.16, the square root of ten.

The same pages mark where the sone scale stops working. Sengpiel says the definition of one sone as 40 phons holds for a sine wave at 1 kilohertz and not for broadband noise, and that at other frequencies the measurement in sones must be calibrated to the frequency response of human hearing. The determination of loudness for stationary signals is defined in ISO 532 or DIN 45631. Sengpiel also warns that the A-weighted decibel reading has nothing to do with sones or phons, and that no formula converts a weighted dBA value into sones or into sound pressure level.

Complex sounds add further complications. The Handbook says the Stevens method of loudness summation is perhaps the most useful for them. A tone that masks another, particularly one of higher frequency, makes it harder to hear, and beats between closely spaced components tend to enhance loudness. When the components lie within a critical bandwidth, the total loudness is the same as a single sine tone with equal sound pressure level, but for tones further apart than a critical band, the loudness contributions of each component, in sones, add together. Short sounds fall off in loudness below a duration of half a second, so to sound equally loud as longer sounds they must be more intense. Exposure to constant tones also decreases their apparent loudness, an effect the Handbook calls adaptation of the ear.

The Question

One unit on which loudness scale is defined by a pure tone at one kilohertz and 40 decibels?

Show the answer

The Answer

Sone. One sone is the loudness of a pure tone with a frequency of one kilohertz and a strength of 40 decibels.