An electrical standard with a carefully specified column of mercury

The mercury resistance standard behind the international ohm

By Phil Springer, Editor · Published · Name That Unit

The mercury resistance standard behind the international ohm

A mercury resistance standard entered United States law on July 12, 1894. The electrical unit associated with it was the international ohm. The statute represented that unit through a column of mercury weighing 14.4521 grams, extending 106.3 centimeters, and having a constant cross section. Its specified temperature was that of melting ice.

Georg Simon Ohm’s own research belonged to an earlier stage of electrical science. J. J. O’Connor and E. F. Robertson’s MacTutor biography places his experimental work in the physics laboratory of the Jesuit Gymnasium at Cologne. In papers published in 1826, he developed mathematical accounts of conduction in circuits. His 1827 book, Die galvanische Kette, mathematisch bearbeitet, presented the wider theory with the mathematical background that he considered necessary. The relationship between current and potential difference became associated with his name.

Recognition came slowly. MacTutor describes his unsuccessful hope that the publications would bring a university appointment, his resignation from Cologne in 1828, and subsequent teaching in Berlin. A position in Nuremberg followed in 1833. The Royal Society awarded him the Copley Medal in 1841 and elected him a foreign member in 1842. Only in 1852 did he obtain the physics chair at the University of Munich. His career and the later standardization of the unit were separate historical developments.

The IEEE History Center’s account of the British resistance project describes the disorder that followed. Telegraph engineers expressed resistance through lengths of particular wires. British practice included miles of copper wire, while French and German material standards used iron wire. Such units did not readily translate into one another. In 1860 Werner von Siemens proposed a mercury column one meter long with a cross section of one square millimeter. The proposal supplied a different kind of reference from a particular manufactured wire, although its magnitude did not coincide with the competing standards.

In 1861 the British Association established its Committee on Electrical Standards, with Fleeming Jenkin as secretary. According to the IEEE account, the committee distinguished a unit from its physical standard and sought convenient size, stability, reproducibility, and consistency with other measurements. Its early coils contained loosely wound wire inside copper containers filled with paraffin wax. Official resistance standards were issued in February 1865. Copies were offered for £2 10s, distributing physical examples of an agreed reference beyond the committee’s own experiments.

The mercury resistance standard became part of a larger international arrangement. NIST’s history of electrical units describes the 1893 Chicago International Electrical Congress’s selection of the ohm and ampere as the basis for the other units. A London conference formally accepted that decision in 1908. The associated current standard relied on a silver voltameter, while voltage standards included Weston cells. Agreement on resistance therefore sat within a network of linked electrical measurements, with different physical devices carrying different parts of the system.

NIST illustrates that network with a photograph of F. A. Wolff at the National Bureau of Standards in 1903. He was studying the temperature response of Weston cells with an oil bath and temperature gauge. The cells supplied stable voltage references. In NIST’s account, a cell and a known resistor supplied the reference current for calibrating the silver apparatus. The institutions maintaining electrical standards thus depended on comparisons among devices as well as on the wording of a definition.

The 1894 law itself showed those connections. Alongside the mercury resistance standard, it defined the international volt through its relationship to one international ohm and one international ampere, and also referred to a Clark cell. It assigned the National Academy of Sciences responsibility for publishing detailed specifications concerning the ampere and volt. The statute combined numerical definitions with an explicit task for a scientific institution, recognizing that the practical details extended beyond the unit names alone.

Dean G. Jarrett and Albert F. Rigosi’s NIST history, From Ohm to Quantum Ohm, follows the physical standards into the 20th century. Early manganin resistors suffered from humidity and stability problems. A Rosa design introduced in 1907 enclosed silk-covered wire in mineral oil. Thomas designs developed in the 1930s used bare wire and double walls. Each generation addressed limitations of the earlier objects, while also introducing sensitivities of its own, including effects associated with electrical loading and pressure.

The same history describes measurements showing a discrepancy between the international and absolute ohms, followed by further confirmation during 1936–1939. World War II delayed the international change until January 1, 1948. The bureau’s representation of the ohm then decreased by 495 parts per million. The mercury resistance standard had supplied an internationally intelligible physical reference, but improved measurements eventually exposed the difference between that reference and the absolute unit it approximated.

The Question

Which electrical unit did a U.S. law approved in 1894 represent with a mercury column 106.3 centimeters long?

Show the answer

The Answer

The law specified the international ohm. Its mercury column was 106.3 centimeters long, weighed 14.4521 grams, and was defined at the temperature of melting ice.