A Think Again Media Group publication
Name That Unit

A frozen metal behind an international light measure

The candela standard and the glow of freezing platinum

By Phil Springer, Editor · Published · Name That Unit

The candela standard and the glow of freezing platinum

The candela standard acquired an unusually demanding physical reference: a glowing black body at the temperature of freezing platinum. In 1967, the General Conference on Weights and Measures specified a radiating surface of 1/600,000 square meter, viewed in the perpendicular direction, under a pressure of 101,325 newtons per square meter. The candela measured luminous intensity. Its international name had been adopted in 1948, following decades of comparisons among flame standards, electric lamps, and heated materials.

NIST's historical account describes the difficulty of establishing a common reference when candles themselves differed. Wick dimensions and the material forming a candle affected the source being compared. In 1879, the French physicist Jules Violle attempted a different reference by heating platinum to its melting point and associating luminous intensity with the metal's glow. NIST characterizes the proposal as difficult to reproduce with the methods available in the 19th century. The heated-metal approach preceded the international agreement that eventually incorporated freezing platinum into a definition.

American laboratory practice also passed through a stage of calibrated electric lamps. Around 1903, the National Bureau of Standards established its first national luminous-intensity reference using carbon-filament lamps compared with Hefner flame standards. Comparisons involved national laboratories and several kinds of flame source, including the French Carcel and English Vernon-Harcourt standards. In 1909, England, France, and the United States adopted the international candle, while the German Hefner candle was treated as 0.9 of that unit. The candela standard emerged from an international measurement history containing several competing physical references.

The historical appendix to NIST's Special Publication 330 distinguishes the successive institutional decisions. The International Commission on Illumination and the International Committee for Weights and Measures had prepared the black-body proposal before 1937. The committee promulgated its decision in 1946, and the General Conference ratified it in 1948. That conference also adopted the name candela and the symbol cd. In 1954, luminous intensity and its unit joined the base quantities and units of the practical system under development. The international system's organization and the physical definition therefore followed related but separate decisions.

The 1967 resolution described its task as a revision of wording. It accepted that the preceding definition fixed the unit satisfactorily, while recognizing criticism of its expression. Its replacement specified the direction, surface area, platinum freezing temperature, and pressure together. Those conditions belonged to the formal candela standard; a reference merely to glowing platinum omitted parts of the conference's actual specification. The resolution also traced its authority through the 1946 committee decision, the 1948 ratification, and powers conferred by the conference in 1933.

A different concern appeared in the conference's 1979 resolution. National laboratories had devoted substantial effort to black-body realizations, yet their results still diverged excessively. Meanwhile, radiometric techniques had developed sufficiently to offer comparable precision, and laboratories were already realizing the unit without constructing the specified black body. The resolution explicitly connected the change to easier realization and improved precision. Its supporting considerations recorded the committee's 1977 adoption of 683 lumens per watt for monochromatic radiation at a frequency of 540 trillion hertz.

The replacement definition retained a specified direction but described a radiation source through frequency and radiant intensity. At 540 trillion hertz, a radiant intensity of 1/683 watt per steradian corresponded to one candela. The conference formally withdrew the earlier definition, identifying its adoption, ratification, and amendment in the decision itself. The candela standard thus ceased to require the platinum black body as its defining reference, although the resolution emphasized satisfactory continuity between the old and replacement systems.

A 1994 investigation by Yoshihiro Ohno, C. L. Cromer, Jonathan Hardis, and George Eppeldauer documented NIST's subsequent detector-based realization. The laboratory developed eight photometers containing silicon photodiodes, filters, and precision apertures. Their calibration was linked to an absolute spectral-responsivity scale based on a cryogenic radiometer. The preceding American scale had involved a gold-point black body, reference lamps, and a longer calibration chain. The investigators identified uncertainty in the gold-point temperature and accumulated uncertainty along that chain as limitations of the earlier arrangement.

The eight photometers also supplied a group whose consistency could be examined experimentally. Each measured five lamps with internally frosted bulbs. The measured illuminance values varied by 0.13 percent, expressed at one standard deviation; the investigators attributed the variation to random calibration errors. Corrections reduced the variation while preserving the group average. The resulting illuminance scale had a combined standard uncertainty of 0.19 percent, almost a factor of two smaller than the preceding NIST scale. NIST then maintained the photometer group for its candela scale instead of maintaining luminous-intensity standard lamps. A unit formerly defined through a hot radiating surface had acquired a laboratory realization centered on calibrated detectors.

The Question

Which luminous-intensity unit did a 1967 definition tie to a black body at the freezing point of platinum?

Show the answer

The Answer

The candela. The 1967 General Conference on Weights and Measures defined it through radiation perpendicular to a specified area of a black body at freezing platinum, under a specified pressure.

Send this question to a friend

Read next

By clicking “Send me the first one” you agree to Name That Unit’s Terms of Use and Privacy Policy.